Flame Proof Motor / INNOMOTICS XP Motors

Flame Proof Motor / INNOMOTICS XP Motors
Flame proof efficiency and protection all in one

Innomotics Moves! Flame proof motors combine high efficiency with reliable protection in a single robust package. Designed for hazardous environments, these motors ensure safe operation by preventing ignition of explosive gases, while delivering exceptional performance and energy savings. Ideal for demanding industries, Innomotics Moves! offers the perfect balance of safety and efficiency to keep your operations running smoothly and securely.

Innomotics Moves
Innomotics XP motors are impressive for their extremely long service life and absolute reliability underthe most extreme conditions.
They're also incredibly user-friendly, from their selection and ordering to engineering, integration. commissioning operation, & service.

Shaft Height 80 - 280 for 2P, 4P & 6P
Power Range, Pole 0.75kW to 90kW, 2P | 0.55kW to 90kW, 4P | 0.37kW to 55kW, & 6P
Frame Cast Iron
Efficiency Class IE3
Type of Protection Ex db (Ex tb & Ex tc are available on request)
Temperature Class T4
Ambient Temperature 50°C
Applicable Standards Efficiency Classification according to IEC 60034-30-1
Degree of ingress protection IP66
Voltages 415V (standard) (Aditional voltages available. Refer Siemens Product Configurator for more details
Frequency 50Hz
Type Of Construction IMB3 (Refer Siemens Product Configurator for other construction variants.)
Cooling Method IC411 Totally enclosed fan cooled [TEFC]
Temperature Rise 155°C (F) utilized to 130°C (B) on VFD supply at nameplate kW
Insulation System VFD Sutable insulation scheme for voltage up to 415V as a standard.
Impulse Voltage Insulation Class (IVIC) for Un 415V C (Severe)
As per Std. IS/IEC 60034: Part 18: Sec 41

Additional Information:
  • • RHS / LHS terminal box are available as option from fame size 90 onwards.
  • • CE compatible design motors & higher efficiency at 75% load.
  • • Aux. terminal box casted in FS 250 & 280 leads to lesser joints & Increases robustness ana safety
  • • Best in class validation of enclosure for overpressure test.
  • • Flame path longer than as required by the standard.
  • • VFD fed motors will be provided with PTC thermistors by default. These motors will have aux. nameplate indicating the sate range of operation.
  • • Terminal box having longer extension box across the range.
  • • Cast iron cooling fan as default